SNMP allows you to manage and/or monitor devices on your Q-SYS Q-LAN network for conditions that may need attention. With the use of a third-party MIB (Management Information Base) browser you can poll any Q-SYS device that provides Status information and is connected to Q-LAN.
Depending on the browser you select, you can access the Q-SYS information using SNMP v2c and/or SNMP v3. The parameters for each version are set in the Q-SYS Administrator, SNMP tab. The parameters must be set to the same values in the MIB browser. The information in the tables below explains the SNMP access parameters.
NOTE: The Trap feature of SNMP is not available with Q-SYS at this time.
You must load the Q-SYS MIB into a MIB Browser to access the Q-SYS SNMP objects by name.
NOTE: You can put the MIB anywhere as long as the MIB browser has access to the location.
Each device in the Q-SYS design's Inventory has an entry with the following objects:
invDeviceName (Read Only) – the name of the Inventory device
invDeviceType (Read Only) – the type of Inventory device (Core, Peripheral, Page Station, Amplifier, Streaming I/O, Touch Screen )
invDeviceModel (Read Only) – the specific model of the Inventory device
invDeviceLocation (Read Only) – the Location of the Inventory device
invDeviceStatus (Read Only) – the Status string
invDeviceStatusValue (Read Only) – the Status value ( 0 = OK, 1 = Compromised, 2 = Fault, 3 = Absent, 4 = Unknown, 5 = Initializing)
Each Snapshot Bank has an entry with the following objects:
ssSnapshotName (Read Only) -- the Name of the Snapshot Bank
ssSsTotalSnapshots (Read Only) – the total available snapshots in the Snapshot Bank
ssActiveSnapshot (Read/Write) – Sets the active Snapshot
ssRampTimeSec (Read/Write) – Sets the time it takes for the controls to reach the saved position or value (in seconds) .
NOTE: For all other Q-SYS SNMP objects, please see MIB file.
The settings for these controls must be the same (where appropriate) in the MIB browser and on the Q-SYS Core.
Control |
Function |
Default/Range |
---|---|---|
Access |
Controls permissions to the SNMP. |
Default = Read/Write Range =
|
Community |
A string of text set up in the MIB browser and on the Core using Q-SYS Administrator. The string must match. |
N/A |
Control |
Function |
Default/Range |
---|---|---|
Access |
Sets the level of permissions available when using SNMP. |
Default = Read/Write Range =
|
User |
The username used to access the SNMP information. The username entered in the MIB browser must match this name. |
|
Security Level |
|
Default = No Authorization Range =
|
Password (Authorization no Privacy) |
This password is available when you select either Authorization no Privacy or Authorization and Privacy. The password is encrypted and masked. The password must be a minimum of 8 characters. |
N/A |
Auth Protocol |
Select either MP5 or SHA. Both of these are ways to encrypt the signature attached to the SNMP message. |
Default = MP5 Range = MP5 or SHA |
Password (Authorization and Privacy) |
This password is available when you select Authorization and Privacy which encrypts the entire SNMP message. The password is encrypted and masked. The password must be a minimum of 8 characters. |
N/A |
Encryption |
Select either AES or DES encryption. |
Default = DES Range = DES or AES |
© 2009 - 2016 QSC, LLC. All rights reserved. QSC and the QSC logo are trademarks of QSC, LLC in the U.S. Patent and Trademark office and other countries. All other trademarks are the property of their respective owners.