Parametric Equalizer Component

The Parametric Equalizer is a variable equalizer allowing you to individually adjust the Gain, Bandwidth and center Frequency of up to 32 frequency bands. You can also Bypass individual bands. Master controls, affecting all bands, include Bypass, Invert, Mute and Gain. Additionally, you can change any or all of the bands to either a high or low-shelf equalizer, allowing you to vary the gain of all frequencies, as a group, above or below a selected frequency. At the selected Frequency, the gain changes approximately +3dB or -3dB depending on wether the shelf is adding or reducing gain.

Controls

General

Control Name

Function

Range / Values

Response Panel

The Response panel provides vertical and horizontal cross-hairs with a dynamic frequency and level read-out. Place the mouse courser over the graph to activate the cross-hairs. When the Phase control is activated, the horizontal cross-hair line to the left of center represents the normal curve, the right side represents the phase curve. The readout is only for the normal curve.

X-Axis = Frequency, 20Hz to 20kHz

Y-Axis Left = dB, -24dB to 24dB

Y Axis Right = Phase, -180° to 180°

All (Bands)

A toggle button that activates a graphical display all bands of the equalizer. When the button is not enabled, the Response Panel displays a composite of all the bands. The composite cannot be turned off.

On/Off

Phase

Turns the Phase curve display on and off.

Off/On

Master

Control Name

Function

Range / Values

Bypass

Bypasses all bands of the equalizer.

Off/On

Invert

Inverts the output signal of the equalizer.

Normal/Inverted

Mute

Mutes the output of the equalizer.

Off/On

Reset

Returns all of the band controls to their default positions.

N/A

Band

Control Name

Function

Range / Values

Bypass

Bypasses an individual frequency band.

Off/On

Gain

(dB)

Controls the gain for an individual frequency band.

Default = 0

Range = 0 to 40

Bandwidth

(Octave)

Sets the Bandwidth of an individual band of the equalizer. This is not active when either Low-shelf or High-shelf Type is selected.

Default = 1.0

Range = 0.01 to 1

Frequency

(Hz)

Sets the center Frequency of an individual band.

Default = 1

Range = 20 to 20000

Type

Selects the type of equalizer for that band.

Default = Parametric

Choices - High-shelf, Low-shelf, Parametric

1. The default is different for each band, and depends on number of bands.

Properties

Property

Function

Value

Band Count

Sets the number of bands available in the Equalizer.

1 to 32

Type

Sets the type of input/output channels. Multi-Channel enables the Count Property.

Mono

Stereo

Multi-Channel

Count

Sets the number of input/output channels for Multi-Channel.

2 to 256

Enabled

Enables or disables the graphical Response graph.

Yes / No

Size

Sets the size of the graphical Response graph.

Small / Medium / Large

Control Pins

Pin Name

Value

String

Position

Pins Available

(band) Bandwidth

.010 to 1.00

.010 to 1.00

0.000 to 1.00

Input / Output

(band) Bypass

0

1

active

bypass

0

1

Input / Output

(band) Equalizer Type

1

2

3

Parametric

Low-shelf

High-shelf

0

0.5

1.00

Input / Output

(band) Frequency

10 to 20000

10 Hz to 20 kHz

0.000 to 1.00

 

(band) Gain

-18 to 18

-18 dB to 18 dB

0.000 to 1.00

Input / Output

Master Bypass

0

1

active

bypass

0

1

Input / Output

Master Gain

-20 to 20

-20 dB to 20 dB

0.000 to 1.00

Input / Output

Master Invert

0

1

normal

invert

0

1

Input / Output

Master Mute

0

1

unmute

mute

0

1

Input / Output

Master Reset

trigger

Related Topics Link IconRelated Topics


 

© 2009 - 2016 QSC, LLC. All rights reserved. QSC and the QSC logo are trademarks of QSC, LLC in the U.S. Patent and Trademark office and other countries. All other trademarks are the property of their respective owners.