DataPort Card (CODP4)

This topic covers the hardware aspects of the Q-SYS DataPort Card. For detailed information about the functionality of the DataPort Card, refer to the DataPort topic.

Type 2 Hardware

Type 2 hardware provides new cables and connectors between the I/O cards and main boards in Cores and I/O Frames. Due to this change, the Type 2 hardware is not physically compatible with the older hardware. You can still integrate the new I/O Frames and Cores in the same system with older hardware, but the I/O cards are not interchangeable. Type 2 hardware can be identified by a yellow label on the back of the Core and I/O Frame, and the bottom of the I/O cards.

Connections

IMPORTANT:   DataPorts on multi-port amplifiers must be wired to DataPorts on the same I/O Frame or Core. You cannot wire some of the amplifier's DataPorts to a Core and others, on the same amplifier, to an I/O Frame. You cannot wire some of the amplifier's DataPorts to one I/O Frame and others, on the same amplifier, to another I/O Frame.

DataPort (CODP4)

Dynamic range

un-weighted

> 114 dB

A-weighted

> 117 dB

 

Distortion
(20Hz - 20 kHz)

+4 dBu (max)

2 dB below clip (max)

< 0.04% THD+N

 

Crosstalk
(20 Hz - 20 kHz)

Inter-channel (max)

> 95 dB

Inter-channel (typ)

> 100 dB

Intra-channel (max)

> 100 dB

Intra-channel (typ)

> 110 dB

 

Frequency Response

20Hz - 20 kHz (max)

± 0.5 dB

20Hz - 20kHz (typ)

± 0.2 dB

 

Input Impedance

Balanced (nominal)

Unbalanced (nominal)

 

Common Mode Rejection

20Hz - 20kHz (Min)

20Hz - 20kHz (Typ)

 

Input Sensitivities

Vrms

dBu

dBv

 

Mute

Electro-mechanical relays

Infinite Attenuation

 

Audio Converters

Group Delay (at 48 kHz)

Analog to Digital Conversion (ADCs)

Digital to Analog Conversion (DACs)

24-bit delta-sigma at 48 or 96 kHz sample rate

Output

0.25 ms

 

Connectors

 

Two DE-15 (female 15-pin high-density D shell) connectors

 

User-configurable Options

(software enabled)

Phantom Power

Input Sensitivity

Output Trim

Vrms (max)

dBu (max)

dBv (max)

 

Amplifier Standby

Set or clear amplifier in standby mode

Mute

Set or clear individual channel mutes

Enable Meters

Enable data collection of meters for each channel

Audio Output Levels

Adjust individual audio channel levels

 

Amplifier Model Support

 

CX, PowerLight™ 3 Series, DCA, and legacy V1 models