Status (I/O-22)
The I/O-22, in the Q-SYS Designer Inventory list, represents a physical piece of equipment.
The physical I/O-22 is an Input/Output device. Analog input sources can be connected to the I/O-22 and the analog audio is converted to digital audio and sent over the Q-LAN network to the Core for Processing. Likewise, digital audio can be sent from the Core over the Q-LAN network to the I/O-22 which converts the digital signal to analog for local use.
The I/O-22 in the Inventory list has several components under it that are placed in the Schematic for use in your system.
This Topic covers the Status component of the I/O-22.
Controls
I/O-22 Status
Control |
Function |
Default / Range |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID |
When the ID/Identify button, in the Q-SYS Designer Status component, or the Configurator's Network Configuration for the hardware,or on the physical hardware is pressed, the ID buttons in the Configurator and Status component flash, and the LED on the physical Hardware flashes to indicate the association between the three. The indicators will flash for 5 minutes unless you stop them by pressing any one of the buttons. |
Off / On |
||||||||||||
Status LED |
This LED changes color to indicate the current status of the I/O-22. See Status for the meanings of the various colors. |
N / A |
||||||||||||
Status |
Component status is conveyed with the Status LED and Status box, which uses both color and text to indicate the current condition:
|
N / A |
||||||||||||
Clock Offset |
This text field displays the clock difference between the associated I/O-22 and the Master Clock. The unit of measure is indicated in the text readout. |
N / A |
||||||||||||
Grandmaster |
The clock master of the network. See ( http://en.wikipedia.org/wiki/Precision_Time_Protocol#Architecture) |
N / A |
||||||||||||
Parent Port |
The device and interface name that this device is syncing to when it's not the clock master. Usually it is the same as the Grandmaster name. |
N / A |
||||||||||||
Temperature |
Text field indicating the current temperature inside the associated I/O-22, measured in Celsius. Typically about 60° C. |
N / A |
||||||||||||
Details |
You must select Verbose Yes in the Properties for this field to display. Text indicating the Details of any errors occurring with the I/O-22. The information in this field is updated regularly and is cumulative. None of the items listed below display unless there is a value associated with it. If there are values associated with these, call Support.
|
N / A |
||||||||||||
Reset Details |
You must select Verbose Yes in the Properties for this field to display. Click this button to reset the information in the Details field to zero. |
Momentary Off / On |
Power
These four LEDs indicate which power source is being used for the I/O-22.
Control |
Function |
Default / Range |
---|---|---|
POE A |
PoE A (LAN A) is supplied by a POE switch, or an injector. Produces 2 - 3 W average power, 8-10 W peak power from the loudspeaker for ~ 10 seconds |
N / A
|
POE B |
PoE B (LAN B) is supplied by a POE switch, or an injector. Produces 2 - 3 W average power, 8-10 W peak power from the loudspeaker for ~ 10 seconds |
|
POE A Plus |
PoE A Plus (LAN A) is supplied by a POE Plus switch, or an injector. Produces 8-10 W Average output power from the loudspeaker. |
|
POE B Plus |
PoE B Plus (LAN B) is supplied by a POE Plus switch, or an injector. Produces 8-10 W Average output power from the loudspeaker. |
|
Aux Power |
Aux Power is 24 VDC, 30 W, 1.25 A, supplied by an external power supply. Produces 8-10 W Average output power from the loudspeaker. |
Audio Streams
To see both input and output Audio Streams information, you must have cards installed in the slots giving both inputs and outputs. For example, a Line Input card gives you Input Audio Streams, a Line Out card gives you Output Audio Streams.
Control |
Function |
Default / Range |
||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input OK |
LED indicating the status of the Input Audio Stream for LAN A or LAN B. |
N / A |
||||||||||||||
Input Details |
Text indicating the details of the status of the I/O-22 Input Audio Stream. The information in this field is updated regularly and is displayed as running totals. An item is displayed only when the value is not zero. 1
|
N / A |
||||||||||||||
Output OK |
LED indicating the status of the Output Audio Stream for LAN A or LAN B. |
N / A |
||||||||||||||
Output Details |
Text indicating the details of the status of the I/O-22 Output Audio Stream. The information in this field is updated regularly and is displayed as running totals. An item is displayed only when the value is not zero. 1
|
N / A |
||||||||||||||
1. Notes:In Input and Output Audio Streams, accept_count = (early + on_time). This is OK, everything else should be zero.The units are 16 samples, so accept_count should go up by 3000 per second.too_early, too_late, very_late indicate clock sync problems. If Clock Offset is larger than a single digit, check the QoS configuration on the switches for the clock traffic (the highest priority DSCP). If too_late or very_late are not zero but the Clock Offset is zero or very small, check the QoS configuration on the switches for the audio traffic (the second highest priority DSCP).missing_count could mean network problems such as bad cables, check the CRC error counters on the switches. |
Properties
I/O-22
The following properties are set when the I/O-22 in the Inventory list is selected. They are also available, with the exception of Verbose, when any of the I/O-22 components are in the Schematic and selected.
Property |
Function |
Choices |
---|---|---|
Name |
Identifies the I/O-22 component in Q-SYS Designer, enabling the connection between the design and the physical I/O-22. This name should be the same as the I/O-22 Device Name (hostname) in the Configurator. Click in the Name property and type the Name. The name must follow standard naming conventions, restricted to the following: ASCII characters a - z (case insensitive) Digits 0 - 9 Hyphen (cannot be at the beginning or end of the name) Underscore (acceptable with a Q-SYS implementation) No other characters, symbols, punctuation, or blank spaces. |
User input |
Location |
User defined Location for the I/O-22. |
User input |
Is Network Redundant |
Determines if the I/O-22 is using redundant networks or not. |
|
Is Required |
When Is Required is set to Yes, an error displays if the hardware does not exist on the network. This is the default behavior. When Is Required is set to No, the device is identified as not present, its status state is Not Present which is not considered an error. The color displayed for "Not Present" equipment is gray. If a device is dynamically assignable but has not been assigned, it is considered Not Present" even if it is required. |
Yes / No |
Dynamically Paired |
Indicates that this virtual component can be paired with the same type of hardware without changing the network id of the hardware, or the name of this component. Refer to the Q-SYS Core Manager Dynamic Pairing topic for more information. |
Yes / No |
Verbose |
Displays the Networking and Audio Stream details for LAN A and LAN B. You must have Is Network Redundant set to Yes to see LAN B details. The Verbose property is available only when you select the I/O-22 Component in the Schematic. |
|
Control Pins
The I/O-22 in the Inventory list has no Control Pins. The available Control Pins for the I/O-22 Status Component depend on settings in Properties.
Pin Name |
Value |
String |
Position |
Pins Available |
---|---|---|---|---|
Aux Power Active |
0 1 |
false true |
0 1 |
Output |
Clock Offset From Master |
– |
0 ms to n ms |
– |
Output |
Details |
text field |
Output |
||
Identify |
0 1 |
false true |
0 1 |
Input/Output |
I/O-22 Status |
text field |
Output |
||
LAN A Input Stream Details |
text field |
Output |
||
LAN A Input Stream OK |
0 1 |
false true |
0 1 |
Output |
LAN A Output Stream Details |
text field |
Output |
||
LAN A Output Stream OK |
0 1 |
false true |
0 1 |
Output |
LAN B Input Stream Details |
text field |
Output |
||
LAN B Input Stream OK |
0 1 |
false true |
0 1 |
Output |
LAN B Output Stream Details |
text field |
Output |
||
LAN B Output Stream OK |
0 1 |
false true |
0 1 |
Output |
POE A Active |
0 1 |
false true |
0 1 |
Output |
POE A Plus Active |
0 1 |
false true |
0 1 |
Output |
POE B Active |
0 1 |
false true |
0 1 |
Output |
POE B Plus |
0 1 |
false true |
0 1 |
Output |
Reset Details |
trigger |
Input/Output |
||
Temperature |
nn.n |
nn.n°C |
0 to 1.00 |
Output |
USB Current Limit A |
0 1 |
disabled enabled |
0 1 |
Input/Output |
USB Current Limit B |
0 1 |
disabled enabled |
0 1 |
Input/Output |