CXD-Q Amplifier Out Component

The CXD-Q Amplifier Out component is used to send digital audio over Q-LAN, to the CXD-Q output channels where it is converted to analog audio then amplified. This component provides the inputs to the output stage of the amplifier. All audio sent to the amplifier output section is from this component via Q-LAN.

The analog audio input to the Line Inputs on the rear of the amplifier is converted to digital audio and sent to the CXD-Q Input component via Q‑LAN.

Add the amplifiers to the Inventory list based on the physical amplifiers in your system. Each amplifier in the Inventory list has Components associated with it that are placed in the Schematic for configuration and wiring. The CXD-Q Amp Output Control Panel is used for telemetry, and amplifier control of On / Standby, Mute, and Gain. The same controls are available on the amplifier's front panel.

Inputs

The inputs are digital audio from any appropriate component within Q-SYS Designer. There can be from one to four inputs (four channel models) or two to eight inputs (eight channel models) and is dependent on the FAST configuration. The eight channel models have two sets of four channels.

Outputs

The outputs are digital audio connecting to loudspeaker components.

70V, 100V Mode

The CXD-Q amplifiers are capable of supplying 70V or 100V outputs. In order to use this mode, you must connect an appropriate loudspeaker component to the CXD-Q Out component. For QSC loudspeaker components, capable of using 70V or 100V, set the Mode Property of the loudspeaker component to either 70V or 100V. Q-SYS sets the amplifier to this mode when the design is deployed.

In addition, when an amplifier is set to either 70V or 100V mode, a 50 Hz high-pass filter is automatically added in line to protect the loudspeakers.

CXD4.2Q

In order to set the CXD4.2Q amplifiers to 70V or 100V mode you must configure the outputs to channels A and B bridged, and channels C and D bridged (A+B C+D).

Controls

Amplifier Status

Control

Function

Default / Range

Status

Displays the current status of the amplifier both in text and color. The following is a list of possible status colors, and some example conditions.

Note: These conditions are examples, and may not be applicable to all components with a Status field.

OK – Green – (0) – Audio is good, hardware is good.

Compromised – Orange – (1) – Audio is good but a redundancy mechanism is active (one LAN down but the other is still up) or a non-fatal hardware problem exists (fans too slow, temperature higher than expected, etc.)

Fault – Red – (2) – Audio is not passing, or hardware is malfunctioning or mis-configured (amplifier power off, audio streams broken, wrong type of I/O Card installed, loudspeaker short circuit, etc.)

Missing – Red – (3) – A piece of hardware, defined in the design, has not been discovered. Audio is not passing through that piece of hardware.

Initializing – Blue – (5) – In the process of firmware, configuration update, and design start. Audio is obviously bad.

Not Present – Gray – A virtual component in the design, that is designated as Dynamically Paired, and Not Required ,has no hardware assigned to it.

N / A

On/Standby

Button controls the amplifier from Standby to Power On and back.

Standby

Power On

Mute All

Mutes all channels of the amplifier. Once Mute All is engaged, you must use the Mute All button to unmute the channels. The individual channel Mute is disabled while the Mute All is engaged.

Mute/Unmute

Gain Lock

Disables the gain control on the front panel of the amplifier. The gain controls in the Q-SYS Designer component are not disabled.

Disabled/Enabled

Mute Lock

Disables the mute controls on the front panel of the amplifier. The mute controls in the Q-SYS Designer component are not disabled.

Disabled/Enabled

AC Voltage

The AC Mains voltage.

100 VAC to 240 VAC

AC Current

The AC Mains current being drawn by the amplifier.

 

PSU Temp

Temperature of the amplifier's power supply.

55° C = Compromised State

63° C Mutes Audio

V Rail 1

Internal amplifier voltage monitor.

147VDC +/- 5V typical

V Rail 2

Internal amplifier voltage monitor.

-147VDC +/- 5V typical

Fan RPM

The fan speed varies based on the temperatures.

N / A

Meter Select

Selects either RMS or Peak for the five meters in all channels. Changing the meter type changes the meter readings on the CXD-Q Out component and on the amplifier output gain meters.

RMS/Peak

Standalone (test button) This control is available only in Standalone mode only. Press this button to simulate Standalone mode. You will hear the audio that is played when the amplifier is in the Standalone Mode. Off / On

Channel (A, B, C, D), (and E, F, G, H for eight channel) Status

Control

Function

Default / Range

Channel

The channel letter changes based on the FAST™ (Flexible Amplifier Summing Technology) selection in the Properties.

Single channels = A (or B, C, D) ( 8CH E, F, G, H)

Parallel channels = AB (or CD) (8CH EF or GH)

Bridged channels = A+B (or C+D) (8CH E+F or G+H)

Refer to Properties "FAST Mode"

Default = Four separate channels –

A, B, C, D

(and E, F, G, H for 8-channel)

Gain

The Gain knob adjust the digital gain of the associated output channels.

Default = 0 dB

Range = -100 dB tp +20 dB

Mute

Mute button mutes the associated channel of the amplifier. Linked to the Mute button on the amplifier.

Off / On

Over Current

Red LED indicating an over current condition exists in the associated amplifier channel.

False / True

DAC Limit

Red LED indicating that signal to the D to A Converter is larger than can be reproduced and a limiter has been engaged to prevent clipping. This is an indication that the gain structure is not correct.

 

False / True

Protect

Red LED indicating that the channel is in Protect Mode. Usually due to attempting to drive too low an impedance for too long.

False / True

Limit

Red LED indicating that the amplifier is in the limiting mode. This occurs if the signal is driving the power, current, or voltage above the amplifier rated values or due to thermal limiting.

False / True

Short

Red LED indicating there is a short in the loudspeaker circuitry.

False / True

Temp

Displays the temperature, in Centigrade, of the associated channel.

N / A

Channel (A, B, C, D) Meter

These readings can be RMS or Peak depending on the Meter Select setting.

Control

Function

Default / Range

Input

(dBFS)

Measures the digital input to the amplifier output channel.

Range = -100 to 20

Voltage

(V)

Measures the voltage of the amplifier / loudspeaker circuit.

Range = 0 - 150

Current

(A)

Measures the current of the amplifier / loudspeaker circuit.

N / A

Power

(W)

Measures the power of the amplifier / loudspeaker circuit.

N / A

Headroom

(dB)

Measures the amount of headroom left before reaching the amplifier's maximum capabilities.

N / A

Monitor

There is one Listen button and one Gain control for each channel.

Control

Function

Default / Range

Listen

The Listen button activates the Loudspeaker monitor for the associated channel.

Off / On

Gain

(V)

The Gain knob controls the output gain to the Loudspeaker Monitor component.

Range = -100 to +20

Standalone

There is one Mute button and one Gain control for each channel.

Control

Function

Default / Range

Mute

Mutes the output of the amplifier channel when in Standalone Mode.

Off / On

Gain

(dB)

Controls the Gain of the amplifier's output when in Standalone mode.

Default = 0

Range = -100 to 20

Properties

Refer to the CXD-Q Amplifier Status Component topic Properties.

Control Pins

The available Control Pins depend on settings in Properties.

Amplifier

Pin Name

Value

String

Position

Pins Available

AC Current

 

 

 

Output

AC Mains Voltage

100 - 240

100V - 240V

0V = 0

120V = .5

240V = 1.00

Output

Fan Speed

 

 

 

 

Gain Lockout

0

1

disabled

enabled

0

1

Input / Output

Mute All

0

1

unmute

mute

0

1

Input / Output

Mute Lockout

0

1

disabled

enabled

0

1

Input / Output

Peak/RMS Select

0

1

Peak

RMS

0

1

Input / Output

Power On

0

1

Standby

On

0

1

Input / Output

Power Supply Temp

n

n °C

0.000

1.000

Output

Rail 1 Voltage

142 to 152

142V to 152V

0.000

1.000

Output

Rail 2 Voltage

-142 to -152

-142V to -152V

0.000

1.000

Output

Status

0

1

2

3

4

OK (green)

Compromised (orange)

Fault (red)

Unknown (red)

Updating (blue)

0

0.250

0.500

0.750

1.00

Output

Channel (A, B, C, D) (and for 8-channel E, F, G, H)

Pin Name

Value

String

Position

Pins Available

Current

0 to 70

0 A to 70 A

0.000

1.000

Output

DAC Output Limit

0

1

false

true

0

1

Output

Gain

-100 to 20

-100 dB to 20 dB

0.000

1.000

Input / Output

Headroom

0 to 70

0 dB to 70 dB

0.000

1.000

Output

Input Meter

-100 to 20

-100 dB to 20 dB

0.000

1.000

Output

Limit

0

1

false

true

0

1

Output

Monitor Gain

-100 to 20

-100 dB to 20 dB

0.000

1.000

Input / Output

Monitor Listen

0

1

disabled

enabled

0

1

Input / Output

Mute

0

1

unmute

mute

0

1

Input / Output

Over Current

0

1

false

true

0

1

Output

Power

0 to 10000

0 W to 10,000 W

0.000

1.000

Output

Protect

0

1

false

true

0

1

Output

Short

0

1

false

true

0

1

Output

Temperature

Text Field

 

Voltage

0 to 150

V to 150 V

0.000

1.000

Output

Software and Firmware | Resources | QSC Self Help Portal | Q-SYS Help Feedback