DataPort Amplifier Backup Panel (DAB-801 )

Note: This topic is for reference only. Refer to the DAB-801 Hardware Installation Manual for installation instructions.

The purpose of the DataPort Amplifier Backup Panel is to provide the redundancy and other functionality required by most Life-Safety/Evacuation systems. In order to meet those requirements, the DAB-801, when used in a Q-SYS system, must be used with QSC DataPort amplifiers and Q-SYS I/O Frames with DataPort cards installed. All of the amplifiers connected to a DAB-801, or a set of stacked DAB-801s, must be the same model/channel count.

The DAB-801 is intended to mount on rear rack rails, or behind an amplifier rack.

The DAB-801 provides N+1 amplifier redundancy for QSC 2 and 4-channel DataPort amplifiers, and supports I/O Frame redundancy. Two DAB-801s can be stacked to provide double the primary amplifier redundancy.

Note: The DAB-801 does not support 8-channel amplifiers.

For complete details refer to the Amplifier Redundancy topic.

DAB-801 Connectors

One DAB-801 can connect:
- Four 2-channel or two 4-channel primary amplifiers with one 2-channel or one 4-channel backup amplifier,
- One primary I/O Frame with 2 DataPort cards, and one backup I/O Frame with two DataPort cards,
- Eight facility loudspeakers

#

Connector Name on DAB-801

Connector Type

Connects To

1

Primary Q-SYS GPIO

DA-15

Primary Q-SYS I/O Frame GPIO

2

Control Extension Bus

DC-37

Extension or second DAB-801

3

Backup Q-SYS GPIO

DA-15

Backup Q-SYS I/O Frame GPIO

4

Primary Q-SYS DataPorts - A - Ch1 - Ch2

DE-15 (Pinout)

Primary Q-SYS I/O Frame DataPort (Ch1 - 2 1)

5

Primary Q-SYS DataPorts - B - Ch3 - Ch4

DE-15

Primary Q-SYS I/O Frame DataPort (Ch3 - 4 1)

6

Backup Q-SYS DataPorts - A - Ch1 - Ch2

DE-15

Backup Q-SYS I/O Frame DataPort (Ch1 - 2 1)

7

Backup Q-SYS DataPorts - B - Ch3 - Ch4

DE-15

Backup Q-SYS I/O Frame DataPort (Ch3 - 4 1)

8

Backup Q-SYS DataPorts - C - Ch5 - Ch6

DE-15

Backup Q-SYS I/O Frame DataPort (Ch5 - 6 1)

9

Backup Q-SYS DataPorts - D - Ch7 - Ch8

DE-15

Backup Q-SYS I/O Frame DataPort (Ch7 - 8 1)

10

Primary Q-SYS DataPorts - C - Ch5 - Ch6

DE-15

Primary Q-SYS I/O Frame DataPort (Ch5 - 6 1)

11

Primary Q-SYS DataPorts - D - Ch7 - Ch8

DE-15

Primary Q-SYS I/O Frame DataPort (Ch7 - 8 1)

12

Power

18 Gauge IEC Power Cord

Facility AC Power Outlet

13

Page Input

6-Position "Euro" or "Phoenix" type (Pinout)

Line Level Input - See Pinout

14

Connect to Facility Speakers - A - Ch1 - Ch2, B - Ch3 - Ch4

8 position high current "Euro" or "Phoenix" type

Facility Loudspeakers 1 through 4

15

Alarm Input

6-Position "Euro" or "Phoenix" type (Pinout)

Line Level Input - See Pinout

16

Alarm / Page Channel Assignment

DIP Switch (Settings)

N / A

17

Primary Amplifier DataPorts - A - Ch1 - Ch2

DE-15

Primary Amplifier DataPort 2

Four 2-channel amplifiers - connects to amp #1, Ch1 - 2

Two 4-channel amplifiers - connects to amp #1, Ch1 - 2

18

Connect to Primary Amplifier

A - Ch1 - Ch2

B - Ch3 - Ch4

8-Position high current "Euro" or "Phoenix" type

Primary Amplifier Loudspeaker connections:

Four 2-Channel Amps: (A) Amp #1 Ch1 - 2 and (B) Amp #2 Ch1 - 2

Two 4-Channel Amp: Amp #1 (A) Ch1 - 2 and (B) Ch3 - 4

19

Primary Amplifier DataPorts - B - Ch3 - Ch4

DE-15

Primary Amplifier DataPort 2

Four 2-channel amplifiers - connects to amp #2, Ch1 - 2

Two 4-channel amplifiers - connects to amp #1, Ch3 - 4

20

Backup Amplifier DataPorts - X - Ch1 - Ch2

DE-15

Backup Amplifier DataPort 2:

2-Channel Amp DataPort (Ch1 - 2)

4-Channel Amp DataPort (Ch1 - 2)

21

Connect to Backup Amplifier - X - Ch1 - Ch2, Y - Ch3 - Ch4

8 position high current "Euro" or "Phoenix" type

Backup Amplifier Loudspeaker connections

2-Channel Amp: X Ch1 - 2, Y (N / A)

4-Channel Amp: X Ch1 - 2, and Y Ch3 - 4

22

Speaker Extension Bus

8 position high current "Euro" or "Phoenix" type

Connects to the Speaker Extension Bus on the Extension DAB-801.

23

Backup Amplifier DataPorts - Y - Ch3 - Ch4

DE-15

Backup Amplifier DataPort 2

2-Channel Amp - N / A

4-Channel Amp DataPort (Ch3 - 4)

24

Primary Amplifier DataPorts - C - Ch1 - Ch2

DE-15

Primary Amplifier DataPort 2

Four 2-channel amplifiers - connects to amp #3, Ch1 - 2

Two 4-channel amplifiers - connects to amp #2, Ch1 - 2

25

Connect to Primary Amplifier - C - Ch5 - Ch6, D - Ch7 - Ch8

8 position high current "Euro" or "Phoenix" type

Primary Amplifier Loudspeaker connections:

Four 2-Channel Amps: (A) Amp #3 Ch1 - 2 and (B) Amp #4 Ch1 - 2

Two 4-Channel Amp: Amp #2 (A) Ch5 - 6 and (B) Ch7 - 8

26

Primary Amplifier DataPorts - D - Ch1 - Ch2

DE-15

Primary Amplifier DataPort 2

Four 2-channel amplifiers - connects to amp #3, Ch1 - 2

Two 4-channel amplifiers - connects to amp #2, Ch1 - 2

27

Connect to Facility Speakers - C - Ch5 - Ch6, D - Ch7 - Ch8

8 position high current "Euro" or "Phoenix" type

Facility Loudspeakers 5 through 8

1. An I/O Frame can have up to four DataPort cards with two 2-channel DataPort connectors on each, for a total of 16 channels per I/O Frame. The DataPort cards can be installed in I/O Frame slots A through D, the lower lettered slot takes the lower numbered channels. Slot A has channels 1 - 4, if there was another card in slot D, it would have channels 5 - 8.
2. The DataPorts on amplifiers are labeled with only "DataPort", but they are associated with the adjacent channels.

DAB-801 Indicators

Primary DataPort Indicators

Backup DataPort Indicators

Installation and Service Notes

Loudspeaker Connections

Loudspeaker wiring from the amplifiers and to the loudspeakers are connected to the DAB-801 using heavy duty, latching Euro or "Phoenix" connectors with non-loosening set screws that accept up to 10 gauge wire. Five 8-pin connectors are provided:

DataPort Connections

DataPort connections use the QSC DataPort cable, with locking DE-15 connectors for secure, stable connections. Each DataPort cable serves two amplifier channels. Each DataPort card has two DataPort connectors.

Note: A QSC DataPort cable is required for connection from the DataPort card to the DataPort amplifier or DAB-801. These appear to be common VGA cables but they are not. Many off-the-shelf VGA cables MIGHT work with satisfactory results, however it is also quite possible off-the-shelf cables will give less-than-satisfactory results, and could even cause damage to QSC DataPort amplifiers! The QSC DataPort specification requires that all conductors be present, as well as shielding over those conductor pairs used for the audio channels to the amplifier. Therefore, QSC recommends the use of QSC DataPort cables exclusively, which are available in a variety of lengths from QSC. Use of any non-QSC DataPort cable may void the warranty.

GPIO Connections

The GPIO from the I/O Frame to the DAB-801 uses locking DA-15 connectors. In a stacked-DAB-801 configuration, the GPIO (from both I/O Frames) connects to the primary DAB-801 only. The control to the secondary DAB-801 is passed through the DC-37 connection between the DAB-801s.

Stacking DataPort Amplifier Backup Panels

A DC-37 connector is used to connect two DAB-801s together, passing DataPort signals and GPIO control to the secondary panel. An 8-pin Phoenix type connector is used to is used for the backup amplifier's loudspeaker connections to the second panel.

Internal logic causes the second panel to automatically number its primary amplifiers 5 thru 8, to avoid conflicts with amplifiers 1-4 connected to the first panel.

AC Power

Each panel has a locking IEC connector and requires 10 W of power, 100-250 Vac. No power switch is provided, to reduce points of failure and to prevent tampering.

LED Indicators

Although Q-SYS provides a complete fault report, to aid on-the-spot servicing, LEDs are provided that show the status of all connected equipment. Green LEDs next to each I/O and amplifier DataPort connection show if the connected device is powered up. When Q-SYS replaces a faulty device it triggers a red LED, and when a backup device is in use, it shows a yellow LED. Use of the Alarm or Page functions will trigger red LEDs next to each Page input.

Connector Pinouts

DataPort DE-15 Connector Pinout

The illustration below shows the pin assignments used for the DataPort DE-15 (female 15-pin high-density D shell) connectors.

This information is shown for reference only and is subject to change without notice as the DataPort feature is specific to QSC products and not intended for interface to other manufacturer's equipment.

This view is of the female chassis connector on the DataPort card.

Pin

Signal Description

Description

1

Channel 1 Minus (-) Signal

Channel 1 Audio (-)

2

AC Standby Control

Places the amplifier in standby

3

V-MON Channel 1

Subcode 1 - Bridge Mode & Power Detect

Voltage on Channel 1

Detects bridge mode of the amplifier

Detects amplifier power on

4

I-MON Channel 1

Subcode 2 - Temperature, Channel 1

Current on Channel 1

Typically amplifier temperature, but may vary depending on amplifier model.

5

Clipping Channel 1

Protect Channel 1

The Clipping indicator goes on immediately if channel 1 is clipping.

The Protect indicator goes on if the amplifier is overheating or has an over-current condition. This condition essentially disconnects the outputs from the amplifier.

6

Hard Ground

Chassis ground

7

Channel 1 Plus (+) Signal

Channel 1 Audio (+)

8

Channel 2 Plus (+) Signal

Channel 2 Audio (+)

9

+15 V from Amplifier

Unused Input

10

Data Reference Ground

Reference for all monitor signals.

11

Channel 2 Minus (-) Signal

Channel 2 Audio (-)

12

Amplifier IDR (Model ID)

Each amplifier contains a resistor with a specific resistance that identifies the amplifier model The resistance is measured by the DPIO.

The amplifier model is used to correctly interpret all other DPIO data and signals.

If the amplifier identified in Q-SYS Designer is different from what is detected, an error is displayed. The model that is detected is used for calculations regardless of the model identified in Q-SYS Designer.

13

V-MON Channel 2

Subcode 3 - Standby Mode Detect

Voltage on Channel 2

When the amplifier is first powered up, it goes into standby mode prior to normal mode and is indicated on this pin. In addition, if the amplifier is placed in the standby mode it is indicated on this pin.

14

I-MON Channel 2

Subcode 4 - Temperature, Channel 2

Current on Channel 2

Typically amplifier temperature, but may vary depending on amplifier model.

15

Clipping Channel 2

Protect Channel 2

The Clipping indicator goes on immediately if channel 2 is clipping.

The Protect indicator goes on if the amplifier is overheating or has an over-current condition. This condition essentially disconnects the outputs from the amplifier.

Alarm/Page Input Connector Pinout

Alarm/Page Channel Assignment DIP Switch

Turning a switch to the On position indicates that if there is an alarm or page announcement, that channel is disconnected from the standard input and connected to the Alarm/Page input. The remaining channels have the option of being muted via settings for the DAB-801 component in Q-SYS Designer.