VOIP Out
VOIP Out component controls the outgoing call signal level. Refer to the Softphone topic for details.
Property |
Function |
Choices |
---|---|---|
Name |
The Name identifies the Softphone component in Q-SYS Designer. The name must follow standard naming conventions, restricted to the following: ASCII characters a - z, A-Z (case insensitive) Digits 0 - 9 Hyphen (cannot be at the beginning or end of the name) Underscore (acceptable with a Q-SYS implementation) You cannot use any other characters, symbols, punctuation, or blank spaces. When you have entered the Name, it displays next to the Softphone icon in the Inventory list, and on the component in the Schematic. |
User input |
Location |
The Location is a means by which you can organize your virtual equipment to correspond to your physical equipment. The Softphone has no physical equipment, so you may want to group this with the Core running the related design. Click in the Location property, the "Default Location" highlights. Type the name of the new location. Once you have entered the new Location name, it is available on the pull-down for the Location property, in addition, the Location lists the Softphone. |
User input |
Tone Output |
When 'Yes' is selected, the Ring, Entry, Exit, and DTMF tones are fed to a separate output channel (Tone Output) on the VOIP In component. These tones can now be routed independent of the voice audio. |
Yes / No |
Control |
Function |
Default / Range |
---|---|---|
Peak Output Level (dBFS) |
Measures the digital output signal level. |
Green = good Yellow = close to clipping Red = clipping |
Clip |
Red LED indicating if the signal is being clipped. |
Off / On |
Clip Hold |
Holds the clip indication until manually cleared. |
Off / On |
Invert |
Inverts the audio signal. |
Off / On |
Mute |
Mutes the digital audio signal. |
Off / On |
Gain |
Controls the gain of the digital audio signal. |
Default = 21 Range = -10 to +21 |
Pin Name |
Value |
String |
Position |
Pins Available |
---|---|---|---|---|
Clip (LED) |
0 1 |
false true |
0 1 |
Input / Output |
Clip Hold (toggle) |
0 1 |
false true |
0 1 |
Input / Output |
Output Gain (level knob) |
-100 to 20 |
-100 dB to 20 dB |
0.000 to 1.00 |
Input / Output |
Output Invert (toggle button) |
0 1 |
normal invert |
0 1 |
Input / Output |
Output Mute (toggle button) |
0 1 |
unmute mute |
0 1 |
Input / Output |
Output Peak Level (level meter) |
-100 to 20 |
-100 dB to 20 dB |
0.000 to 1.00 |
Input / Output |