The touch screen Status / Control component provides the connection between the physical touch screen and the Q-SYS Designer User Control Interface (UCI). In order to make the connection, you must specify the hardware's hostname, network redundancy status, and assign a UCI. Once the physical hardware is identified, the touch screen component provides the hardware status.
For information on supported touch screens, see Q-SYS Hardware.
Note: Make sure you use the proper Q-SYS Designer component for the hardware connected to your Core. The TSC components are not interchangeable.
Control |
Function |
Default / Range |
---|---|---|
ID |
When the ID / Identify button, in the Q-SYS Designer Status component, or the Configurator's Network Configuration for the hardware, or on the physical hardware is pressed, the ID buttons in the Configurator and Status component flash, and the LCD on the physical Hardware flashes to indicate the association between the three. The indicators will flash for 5 minutes unless you stop them by pressing any one of the buttons. |
N/A |
Status LED |
This LED changes color to indicate the current status of the Touchscreen. See Touchscreen Status for the meanings of the various colors. |
N/A |
Touchscreen Status |
Displays the current status of the Touchscreen in both text and color. The following is a list of possible status colors, and some example conditions. OK – Green – (0) – Communication method is good, hardware is good. Compromised – Orange – (1) – Communication is good but a redundancy mechanism is active (one LAN down but the other is still up) or a non-fatal hardware problem exists (fans too slow, temperature higher than expected, etc.) Fault – Red – (2) – No communication, or hardware is malfunctioning or mis-configured (amplifier power off, audio streams broken, wrong type of I/O Card installed, loudspeaker short circuit, etc.) Missing – Red – (3) – A piece of hardware, defined in the design, has not been discovered. Initializing – Blue – (5) – In the process of firmware, configuration update, and design start. Not Present – Gray – A virtual component in the design, that is designated as Dynamically Paired, and Not Required ,has no hardware assigned to it. |
N/A |
Clock Offset (TSC-7t only) |
USB Audio Bridge must not be set to Disable to see this control. This text field displays the clock difference between the TSC-7t and the Master Clock. The unit of measure is indicated in the text readout. |
N/A |
Grandmaster (TSC-7t only) |
USB Audio Bridge must not be set to Disable to see this control. The clock master of the network. See ( http://en.wikipedia.org/wiki/Precision_Time_Protocol#Architecture) |
N/A |
Parent Port (TSC-7t only) |
USB Audio Bridge must not be set to Disable to see this control. The device and interface name that this device is syncing to when it's not the clock master. Usually it is the same as the Grandmaster name. |
N/A |
To see the following items, you must have Is Network Redundant set to Yes, Verbose Set to Yes, and USB Bridging enabled with the Sound Card(s) or Speakerphone in the Schematic.
Control |
Function |
Default / Range |
---|---|---|
Input OK |
Multi-colored LED indicating the status of the LAN connections to the TSC-7t. |
N/A |
Suppress button |
If the "Is Network Redundant" property is set to 'Yes', but the redundant network is not connected, an error is displayed. This button suppresses the error caused by LAN B not being connected. |
Off / On |
Input Details |
Must have Verbose in the TSC-7t Property set to Yes. Details concerning the audio input to the TSC-7t. connected dscp accept_count drop_count discontinuity_count on_time too_late |
N/A |
Output OK |
Multi-colored LED indicating the status of the LAN connections to the TSC-7t |
N/A |
Output Details |
Must have Verbose in the TSC-7t Property set to Yes. Details concerning the audio output from the TSC-7t. connected dscp accept_count drop_count discontinuity_count on_time too_late |
N/A |
To see the following items, you must have Is Network Redundant set to Yes, Verbose Set to Yes, and USB Bridging enabled with the Sound Card(s) or Speakerphone in the Schematic.
Control |
Function |
Default / Range |
---|---|---|
Connection |
LED indicating the presence or absence of a USB Bridging connection. |
false / true |
More |
Displays additional information for the USB Audio Inputs and Outputs. For each input and output, SRC+, SRC-, and Reset is displayed. |
false / true |
The following items have 1 each of the next five controls / indicators. USB NEC (EC) Speakerphone 1 In USB NEC (EC) Speakerphone 1 Out (NEC=Non-Echo Cancelling, EC=Echo Cancelling) USB Sound Card 2 In USB Sound Card 2 Out |
||
Active |
LED indicating the presence or absence of an audio signal. |
false / true |
Samples |
Total number of samples since the audio started, or since the count has been reset. |
N/A |
SRC+ |
The number of samples added in order to match the USB clock with the Q-SYS PTP clock |
N/A |
SRC- |
The number of samples removed in order to match the USB clock with the Q-SYS PTP clock |
N/A |
Reset |
Resets the Sample count for the associated audio device. | N/A |
These controls are found on the Configuration tab for the TSC-7t, the other TSCs display when the control panel is opened.
Control |
Function |
Default / Range |
---|---|---|
Log Off |
If a user is required to log on to the TSC, this button can log them off. Refer to the Q-SYS Core Manager User Control Interfaces topic. |
N/A |
UCI |
Displays the name of the UCI currently running on the TSC. You can change the currently running UCI if the UCI Assignment is set to Dynamic. |
User Defined |
Page |
Displays the name of the currently selected page in the UCI. You can click this field and change the viewed page. |
N/A |
These controls are found on the Configuration tab for the TSC-7t, the other TSCs display when the control panel is opened.
Control |
Function |
Default / Range |
---|---|---|
Backlight |
Controls the brightness of the screen back-lighting. |
0% to 100% |
Dim Timeout (minutes) |
Sets the time from when the screen was last touched until the screen is dimmed. |
0 to 9999 |
Off Timeout (minutes) |
Sets the time from when the screen was last touched until the unit is turned off. If log on is required for the UCI, when this time expires, the user must log on to the UCI again. |
0 to 9999 |
On |
Momentary button to turn the TSC display on. |
N/A |
Dim |
Momentary button to dim the TSC display. |
N/A |
Off |
Momentary button to turn the TSC display off. |
N/A |
Disable Popup Numpad |
When this control is activated, the keypad that displays when you touch a numeric-type control (Gain knob, Fader, Time, and so on) is disabled. The keypad does not display when a numeric-type control is touched. | Off / On |
Touch Activity |
LED indicates if the touchscreen is actively being touched. |
N/A |
Property |
Function |
Choices |
---|---|---|
Name |
Identifies the Touchscreen component in Q-SYS Designer, enabling the connection between the design and the physical Touchscreen. This name should be the same as the Touchscreen Device Name in the Configurator. Click in the Name property and type the Name. The name must follow standard naming conventions, restricted to the following: ASCII characters a - z (case insensitive) Digits 0 - 9 Hyphen (cannot be at the beginning or end of the name) Underscore (acceptable with a Q-SYS implementation) No other characters, symbols, punctuation, or blank spaces. |
User input |
Location |
User defined Location for the Touchscreen. The Location helps to group hardware according to its physical location. |
User input |
Is Network Redundant (Only |
Indicates if the Touchscreen is connected to redundant networks. TSC-7t only: If "Is Network Redundant" is set to Yes, the "USB Audio Endpoints" for the selected TSC-7t are not available. If the "USB Audio Endpoints" Speakerphone or Soundcard is set to Yes, the "Is Network Redundant" property is not available. |
Yes / No |
Is Required |
When the hardware is not connected to Q-LAN: When Is Required is set to Yes, the Status is "Missing" / Red if the hardware does not exist on the network. This is the default behavior. When Is Required is set to No, the Status is "Not Present" which is not considered an error. The color displayed for "Not Present" equipment is gray. If a device is dynamically assignable but has not been assigned, it is considered Not Present" even if it is required. Refer to the Q-SYS Core Manager Dynamic Pairing topic for more information. |
Yes / No |
Dynamically Paired |
Indicates that this virtual component can be paired with the same type of hardware without changing the network id of the hardware, or the name of this component. Refer to the Q-SYS Core Manager Dynamic Pairing topic for more information. |
Yes / No |
Verbose (TSC-7t only) |
Must have one of the USB Audio Endpoints set to Yes. When Verbose is set to Yes, the Input and Output details display in the Control Panel. | |
External USB Audio (TSC-7t only) |
When enabled, you can connect an external audio device to the USB input and route audio to and from that device. See External USB Audio Device In and Out. |
Disabled / Enabled |
Orientation (TSC G2 only) |
Select the orientation to match the touchscreen physical installation. To prevent the need of reinstalling the unit, you can select one of the "flipped" orientations. Note: When installing a touchscreen in portrait orientation, the Orientation property in the touchscreen Status/Control component and the User Control Interface Properties must both be set to 'Portrait'. |
Landscape Landscape (flipped) Portrait Portrait (flipped) |
UCI Assignment |
The choices are Static, only the specified UCI is used, and Dynamic you can select the UCI when the UCI is running. |
Static/Dynamic |
UCI |
This field can be edited only when the UCI Assignment is set to Dynamic. With the UCI Assignment set to Static, the name of the assigned UCI displays in this field, but cannot be changed. Use the pull-down list to select the UCI assigned to this TSC component. |
Based on UCIs defined |
Property |
Function |
Choices |
---|---|---|
USB Bridge Name |
The Name given to the USB Bridge. Default name is from the name in the TSC-7t or I/O-8 Flex network Name, for example, TSC-7t-1. This field cannot be empty. |
User Input |
USB Audio Bridge |
Provides the capability of passing audio via USB. Disabled – Default selection. Speakerphone (1 x 1) – Provides a speakerphone with an input and output component, each having 1 audio connection. Sound Card (2 x 2) – Provides a sound card with an input and output component, each having two (stereo) audio connections. Speakerphone and Sound Card – Provides one speakerphone and one sound card with the same capabilities as described above. Advanced – (I/O-8 Flex Only ) Allows up to any combination of four speakerphone / sound cards. |
|
Speakerphone Mode |
This selection is available only when Speakerphone or Speakerphone and Sound Card is selected in the USB Audio Bridge Property. Indicates if the Q-SYS design has Echo Cancelling or does not have Echo Cancelling. This information is provided to the PC or Mac operating system so it can determine whether or not to use its own echo cancelling. |
Echo Cancelling (EC) Non-Echo Cancelling (NEC) |
Pin Name |
Value |
String |
Position |
Pins Available |
---|---|---|---|---|
Screen |
||||
Backlight |
0 – 100 |
0 – 100% |
0.00 to 1.00 |
Input / Output |
Dim |
Trigger |
Input / Output | ||
Dim Timeout (minutes) |
0 – 9999 |
0 – 9999 |
0 to 1.00 |
Input / Output |
Disable Popup Numpad |
0 1 |
no yes |
0 1 |
Input / Output |
Off |
Trigger |
Input / Output | ||
Off Timeout |
0 – 9999 |
0 – 9999 |
0 to 1.00 |
Input / Output |
On |
Trigger |
Input / Output | ||
Touch Activity |
0 1 |
false true |
0 1 |
Output |
UCI |
||||
Current Page |
Text edit |
Input / Output | ||
Current UCI |
Text display |
Output |
||
Log Off |
Trigger |
Input / Output | ||
Logged In |
0 1 |
false true |
0 1 |
Output |
USB Bridging and USB Audio (Speakerphone and Sound Card – TSC7t Only) |
||||
Active |
0 1 |
false true |
0 1 |
Output |
Reset Counters |
Trigger |
Input / Output | ||
SRC- |
Text display |
Output |
||
SRC+ |
Text display |
Output |
||
Total Samples |
Text display |
Output |
||
USB Connected |
0 1 |
false true |
0 1 |
Output |
TSC-7t Only |
||||
Clock Grandmaster Name (TSC-7t only) |
Text display |
Output |
||
Clock Offset From Master (TSC-7t only) |
– |
0 ms to n ms |
– |
Output |
Clock Parent Port Name (TSC-7t only) |
Text display |
Output |
||
LAN A/B Input Stream Details |
Text display |
|
||
LAN A/B Input Stream OK |
0 1 |
false true |
0 1 |
Output |
LAN A/B Input Stream Details |
||||
LAN A/B Output Stream OK |
0 1 |
false true |
0 1 |
Output |
LAN B Suppress |
0 1 |
false true |
0 1 |
Input / Output |
All TSCs |
||||
Identify |
0 1 |
false true |
0 1 |
Input / Output |
Reboot |
Trigger Input |
Input | ||
Touchscreen Status |
0 1 2 3 4 |
OK (green) Compromised (orange) Fault (red) Unknown (red) Updating (blue) |
0 0.250 0.500 0.750 1.00 |
Output |
Software and Firmware | Resources | QSC Self Help Portal | Q-SYS Help Feedback
Copyright © 2019 QSC, LLC. Click here for trademark and other legal notices. |