The Q-SYS User Control Interface (UCI) provides a means by which a user can control defined parts of a Q-SYS design via a networked device such as the Q-SYS touchscreen controller (TSC) panel, Windows based PC, Apple iPad, iPhone, and others. The UCI is created in Q-SYS Designer, and has one or more pages that can contain controls, indicators, and graphic objects dragged in from the Schematic. Graphic objects and images can also be inserted directly into UCI pages by dragging and dropping, or copying and pasting from other applications (Not all applications support both methods.).
You can deploy and view a UCI on several device types and viewers, including Q-SYS touchscreen controllers, Q-SYS UCI Viewer, UCI Viewer Status\Control component for Windows, and Apple iOS devices. See Deploying User Control Interfaces.
Note: The deployment of a UCI is a licensed feature on certain Cores manufactured with Q-SYS 7.0 and later. For more information, see Licensing.
You can control access to individual UCIs with Q-SYS Core Manager. See User Control Interfaces.
To add controls to a UCI page:
When you open the UCI Design Interface, the working area is defined by a light blue background surrounded by gray area. If you place your cursor in the gray area above or to the left side of the working area, you will see a guide line displayed across or down through the workspace. The guide line moves with the cursor, and coordinates are displayed as you move the guide line.
You can add image files to a UCI in multiple ways.
Note: When you add graphics to a UCI, the images are scaled down for the Panel Type as set in the User Control Interface Properties. The images are never scaled up.
You can add .png, .jpg, .jpeg, .gif, and .svg files to a UCI.
For an .svg graphic to properly display in your UCI, ensure that you configure your graphics application to output an .svg file using the extents of the graphic itself instead of the "document" or "artboard" extents. Exported SVG images must have a width and height defined in the file. For example:
If you select None for the Tabs: Location property (see User Control Interface Properties), you need to provide an alternate navigation method for the user. Q-SYS Designer provides two ways of adding navigation buttons to your UCI. In addition to the navigation type buttons, there are two control type buttons you can add. The Clean Screen button allows you to start a timer on a Q-SYS touchscreen (or in the UCI Viewer), which disables the display for 30 seconds to allow for cleaning. The Log Off Button will log off of the Q-SYS touchscreen if logging in is required.
You can alternatively add a navigation button by dragging a UCI page name into the editor for another UCI page:
Use the toolbar at the bottom of the middle pane to manipulate UCI pages.
Adding layers to your UCI allows you to separate items on your UCI page. When you create a page in the UCI, it will always have at least one layer by default.
You can add a layer to a single page, or create a shared layer that can be used across multiple pages.
You can create shared layers to easily share content between multiple pages. You add content to a shared layer the same as any other layer.
To access the Properties for a UCI, you must select the UCI (not one of its pages) in the left-side pane under User Control Interfaces.
Property |
Function |
Choices |
---|---|---|
Title |
User-defined name to uniquely identify the UCI. The Title does not display unless there is more than one Page for the UCI. |
User Defined |
Style |
Select a CSS style to apply to the UCI. See UCI Styles. |
User Defined |
Panel Type |
Custom – Provides the option to manually set the Orientation, Horizontal Resolution, and Vertical Resolution. Generic – Provides three aspect ratios: 16:10, 16:9, and 4:3. In addition, you can manually set the Orientation. iPad and iPhone (multiple models) – All allow control of the Orientation. TSC-xx – Various QSC capacitive touchscreen models. All allow control of the Orientation. Touchscreen components are found in Inventory > Peripherals. See Status/Control (Touch Screen).
Correcting the Panel Type in older designs
If you open a design originally created in version 5.2 or earlier with a Panel Type that was set to anything other than TSC-3 or TSC-8, the Panel Type may change to an incorrect setting in version 7.0 or later. To correct the Panel Type:
TSC-3 touchscreen font support
The TSC-3 touchscreen only supports the Droid Sans font. |
Custom Generic 16:10 Generic 16:9 Generic 4:3 iPad iPad Mini iPhone iPhone 5 iPhone 6 iPhone 6 Plus TSC-116-G2 TSC-3 TSC-47-G2 TSC-55-G2 TSC-7 TSC-8 TSC-80-G2 |
Orientation |
Set to the orientation of the screen used to display the UCI. Note: When installing a touchscreen in portrait orientation, the Orientation property in the UCI Properties and the Status/Control (Touch Screen) component must both be set to 'Portrait'. |
Landscape Portrait |
Horizontal Resolution |
Available only with the Custom Panel Type. |
1 to 10,000 |
Vertical Resolution |
Available only with the Custom Panel Type. |
1 to 10,000 |
Tabs: Location |
Available when there is more than one UCI page, and the Location Property is not "None". Gives you the option to select the position of the tabs used for navigation between multiple pages. If there is only one page, there are no tabs. Note: If you plan to use Tabs, add them prior to adding any controls. When you add Tabs, the usable area for placing controls changes. |
Bottom Left None Right Top |
Tabs: Style |
Available when there is more than one UCI page, and the Location Property is not "None". Gives you the option of Classic, or Chevron style tabs. |
Classic Chevron |
Tabs: Font |
Available when there is more than one UCI page, and the Location Property is not "None". Determines the font used in tab text. |
(Multiple) |
Tabs: Font Style |
Available when there is more than one UCI page, and the Location Property is not "None". Determines the style applied to the selected font. Available styles differ depending on the selected font. |
(Font-specific) |
Tabs: Font Size |
Available when there is more than one UCI page, and the Location Property is not "None". Controls the size of the font for the tabs as displayed on the UCI. |
6 to 64 |
Tabs: Stroke Color |
Available when there is more than one UCI page, and the Location Property is not "None". Sets the color of the border between the tabs and UCI page. |
(Multiple) |
Tabs: Stroke Width |
Available when there is more than one UCI page, and the Location Property is not "None". Sets the width of the border between the tabs and UCI page. |
1 to 64 |
Swipe Disabled |
Turns the Swipe function on the touchscreen on and off. |
No Yes |
Private |
Set this to Yes to hide this UCI from the iOS and Windows UCI viewers. You will be able to view this UCI on Q-SYS touchscreen controllers connected to your Q-LAN network. |
No Yes |
Enable Button Swipe |
Allows multiple buttons to be activated on a touch screen with a single, continuous finger swipe. As you swipe across multiple buttons, the buttons change state to match the state of the first button pressed. If disabled, each button must be pressed individually. Note: This option is not applicable when controlling a UCI within Q-SYS Designer or the Q-SYS Control app on Apple iOS devices. |
No Yes |
Each page you add has its own Properties.
Property |
Function |
Choices |
---|---|---|
Title |
To identify a UCI Page. Displays as a tab on the left side, and only when there is more than one page. In addition, you can change the Title by clicking the Page listed under the UCI in the User Control Interfaces list. Click the Page, then click directly on the Title to edit it. |
User Defined |
Fill |
Select the background color of each individual UCI page. |
(Multiple) |
Icon |
Select an icon image to appear next to the page tab text. If your UCI only uses one page, no icon is displayed. |
(Multiple) |
To change the properties of a control:
There are several ways you can display a UCI:
Note: Due to the finite amount of memory on any hardware, creating large UCIs can cause performance issues on the device hosting the UCI. Pay particular attention to smaller devices such as those that use the Apple iOS.
Software and Firmware | Resources | QSC Self Help Portal | Q-SYS Help Feedback
Copyright © 2019 QSC, LLC. Click here for trademark and other legal notices. | Q-SYS 8.1.1